Division 8: Frames

OSG: Masonry Frames

Masonry FramesFrames are brake formed to one-half the industry tolerances to guarantee exceptional fit and finish, every time. Quality products at exceptional value.

Standards Met or Exceeded:
  • Meets or exceeds ANSI/SDI A250.6 – 2003 Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames
  • Locations are in accordance with ANSI/DHI A115
  • Meets the requirements of ANSI A250.8 2003 (Commonly known as SDI-100)
Materials:
  • Available in 16 Ga. Cold Rolled or Galvanized steel
  • Tab and slot construction. No welding is required
  • Frame miters are reinforced with 18 ga. Corner gussets to maintain proper alignment
Corrosion Resistance:
  • Frames shall be chemically treated to insure paint adhesion
  • Frames are painted with a baked on two component epoxy rust inhibitive primer
  • All products meet or exceed ANSI A250.1-1998 Salt Spray resistance: Acceptance Criteria for Prime Painted Steel Doors and Frames
Standard Frame Sizes:
  • Single Width 2'0" through 4'0"
  • Paired Width 4'0" through 8'0"
  • Height 6'8", 7'0", 8'0"
Code Compliance:
  • Up to 3 Hour fire rating (UL 63) depending on wall construction

OSG: Dry Wall Frames

Dry Wall FrameFrames are brake formed to 1/2 industry tolerances to guarantee exceptional fit and finish, every time. Quality products at exceptional value.

Standards Met or Exceeded:
  • Meets or exceeds ANSI/SDI A250.6 – 2003 Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames
  • Locations are in accordance with ANSI/DHI A115
  • Meets the requirements of ANSI A250.8 2003 (Commonly known as SDI-100)
Materials:
  • Available in 16 Ga. Cold Rolled or Galvanized steel
  • Tab and slot construction. No welding is required
  • Frame miters are reinforced with 18 ga. Corner gussets to maintain proper alignment
Corrosion Resistance:
  • Frames shall be chemically treated to insure paint adhesion
  • Frames are painted with a baked on two component epoxy rust inhibitive primer
  • All products meet or exceed ANSI A250.1-1998 Salt Spray resistance: Acceptance Criteria for Prime Painted Steel Doors and Frames
Standard Frame Sizes:
  • Single Width 2'6" through 3'0"
  • Double Width 6'0"
  • Height 6'8" and 7'0"
Code Compliance:
  • Up to 1-1/2 Hour fire rating (UL 63) depending on wall construction

OSG: SE Stick

Frames are brake formed to 1/2 industry tolerances to guarantee exceptional fit and finish, every time. Quality products at exceptional value.

Standards Met or Exceeded:
  • Meets or exceeds ANSI/SDI A250.6 – 2003 Recommended Practice for Hardware Reinforcing on Standard Steel Doors and Frames
Materials
  • Available in 16 Ga. Cold Rolled or Galvanized steel
  • Tab and slot construction. No welding is required
  • Frame miters are reinforced with 18 ga. Corner gussets to maintain proper alignment
Corrosion Resistance:
  • Frames shall be chemically treated to insure paint adhesion
  • Frames are painted with a baked on two component epoxy rust inhibitive primer
  • All products meet or exceed ANSI A250.1-1998 Salt Spray resistance: Acceptance Criteria for Prime Painted Steel Doors and Frames
Code Compliance:
  • Up to 1-1/2 Hour fire rating (UL 63) depending on wall construction